IP69 Customized
Waterproof Connector Wiring |
| No | Type | Image | Model | Main Spec | Pin Head |
| 1 | DC to DC |
![]() |
IOP-DCP-02 _DCM2.1-39CM-DCM2.1 |
1. DC 2.1 to DC2.1 |
|
| 2 | DC to DC |
![]() |
IOP-DCP-01 _DCM2.1-160CM-DCM2.1 |
1. DC 2.1 to DC2.1 |
|
| 3 | DC to DC |
![]() |
IOP-DCP-03 _1DCFP-17CM-2DCFP |
1. 1DC FP to 2DC FP |
|
| 4 | RJ-45 to RJ-45 |
|
IOP-C5EMM08-A-RJP01_C5E(MMP8)-260-A-RJP01 |
1. 1 RJ45 to 1 RJ45 |
|
| 5 | M12 to M16 to Ethernet Cable |
![]() |
IOP-M12RM08-A-RJP01 _M12(RMP8)-M16-A-RJP01 |
1. M12 to M16 to RJ45 |
![]() |
| 6 | M12 to M12 to Ethernet Cable |
|
IOP-M12PM08-B-RJP01 _M12(PMP8)-M12-B-RJP01 |
1. M12 to M12 to RJ45 |
![]() |
| 7 | M12 to M12 to DC |
|
IOP-M12RF02-B-DCP01 _M12(RFP2)-M12-B-DCF2.1 |
1. M12 RFP2 to M12 to DC
2. 20CM 3. 18AWG 4. 12A 5. IP68 6. -20 ~ +80℃ 7. 300V |
![]() |
| 8 | M12 to M12 to DC |
|
IOP-M12RM02-B-DCP01 _M12(RMP2)-M12-B-DCF2.1 |
1. M12 RMP2 to M12 to DC
2. 20CM 3. 18AWG 4. 12A 5. IP68 6. -20 ~ +80℃ 7. 300V |
![]() |
| 9 | M12 to M12 to Line |
|
IOP-M12RF02-B-01 _M12(RFP2)-M16-B-01-L |
1. M12 RFP2 to M12 to Line
2. 20CM 3. 18AWG 4. 12A 5. IP68 6. -20 ~ +80℃ 7. 300V |
![]() |
| 10 | M12 to M16 to Line |
|
IOP-M12RF02-A-01 _M12(RFP2)-M16-A-01-L |
1. M12 RFP2 to M16 to Line
2. 20CM 3. 18AWG 4. 12A 5. IP68 6. -20 ~ +80℃ 7. 300V |
![]() |
| 11 | M12 to M16 to DC |
|
IOP-M12RF02-A-DCP01 _M12(RFP2)-M16-A-DCF2.1 |
1. M12 RFP2 to M16 to DC
2. 20CM 3. 18AWG 4. 12A 5. IP68 6. -20 ~ +80℃ 7. 300V |
![]() |
| 12 | M12 to M16 to DC |
![]() |
IOP-M12RM02-A-DCP01 _M12(RMP2)-M16-A-DCF2.1 |
1. M12 RMP2 to M16 to DC
2. 20CM 3. 18AWG 4. 12A 5. IP68 6. -20 ~ +80℃ 7. 300V |
![]() |
| 13 | Outside M12 to DC |
![]() |
IOP-M12CF02-DCJ01 _M12(CFP2)-30CM-DCJ01 |
1. Outside M12 CFP2 to DC
2. 30CM 3. 18AWG 4. 12A 5. IP67 6. -20 ~ +80℃ 7. 300V |
![]() |
| 14 | Outside M12 to DC |
![]() |
IOP-M12CM02-DCP02 _M12(CMP2)-30CM-DCP02 |
1. Outside M12 CMP2 to DC
2. 30CM 3. 18AWG 4. 12A 5. IP67 6. -20 ~ +80℃ 7. 300V |
![]() |
| 15 | Outside M12 to DC |
![]() |
IOP-M12CM02-200CM-DCP01 _M12(CMP2)-200CM-DCP01 |
1. Outside M12 CMP2 to DC
2. 200CM 3. 18AWG 4. 12A 5. IP67 6. -20 ~ +80℃ 7. 300V |
![]() |
| 16 | Outside M12 to RJ-45 |
![]() |
IOP-M12CF08-RJP01 _M12(CFP8)-27CM-RJP01 |
1. Outside M12 CFP8 to RJ45
2. 27CM 3. 18AWG 4. 12A 5. IP67 6. -20 ~ +80℃ 7. 300V |
![]() |
| 17 | N-type to M16 to MMCX |
|
IOP-NFMMC180-A-RG178_NTFD(180)-MMC-A-RG178 | 1. N-type Jack to M16 to
MMCX 2.18CM 3. RG178 4. -30dB 5. IP68 6. -20 ~ +80℃ 7. 16W |
![]() |
| 18 | N-type to M16 to IPEX |
|
IOP-NFIPE250-B-RG178_NTFD(250)-IPE-B-RG178 | 1. N-type Jack to M16 to
IPEX 2.25CM 3. RG178 4. -30dB 5. IP68 6. -20 ~ +80℃ 7. 16W |
![]() |
Welcome to consult OEM / ODM custom business cooperation!!
![]()





|
|